v2.2.0
Known Issues or Limitations
Corstone-1000
Due to limited performance, characters may be dropped if too much data is sent too quickly. Consider inserting delays between characters if sending files or large buffers.
Due to the limited performance, K3s is not currently supported.
Corstone-1000 FVP
RsaPkcs1v15Crypt operations do not work properly due to the limited support in crypto-cell drivers
KV260 with EDK-II
Data abort faults are encountered when using UEFI memory allocation boot services
Known Test Failures
All platforms
The following tests are expected to fail:
AWS Greengrass IoT Device Tester
GGV2Q cloudcomponent and mqttpubsub fail a SignatureException on the device under test
GGV2Q lambdadeployment randomly fails to deploy the test component when run concurrently with mqtt and component tests. This behavior is not observed if this group of tests runs first or if the test suite is executed without this group.
Corstone-1000
The following tests are expected to fail:
AWS Greengrass IoT Device Tester
GGV2Q docker and lambdadeployment tests time out while trying to create a deployment on the device
Setting up Nucleus as a system service may time out when Mender is enabled due to performance limitations
There are failures which are known to occur with the latest release of the Corstone-1000 platform software from meta-arm (CORSTONE1000-2025.05). See Test Report for CORSTONE1000-2025.05.
Corstone-1000 FVP
The following tests are expected to fail:
PARSEC simple E2E tests
Decrypt operations fail with PsaErrorHardwareFailure when using psa-security
Greengrass tests
Provisioning fails due to the RSA limitation. Hence, all IDT tests are expected to fail except for dependency and version checks.
KV260 with U-Boot
The following tests are expected to fail:
ACS BSA tests:
Check Arch symmetry across PE
Check for AdvSIMD and FP support
Check PE 4KB Granule Support
Check Cryptographic extensions
Check Little Endian support
Check EL1 and EL0 implementation
Check for PMU and PMU counters
Check num of Breakpoints and type
Check Synchronous Watchpoints
Check CRC32 instruction support
SYS Timer if PE Timer not ON
Check Arm BSA UART register offsets
16550 compatible UART
ACS EBBR tests:
Same failures for Corstone-1000, along with the following:
BS.ExitBootServices - ConsistencyTestCheckpoint1
RT.SetVariable - Non-volatile variable after system reset
RT.UpdateCapsule - invoke UpdateCapsule with invalid ScatterGatherList
RT.UpdateCapsule - invoke UpdateCapsule with invalid Flags
RT.UpdateCapsule - invoke UpdateCapsule with invalid Flags
KV260 with EDK-II
The following tests are expected to fail:
ACS is expected to fail in all network interface related tests.